Gap-Filling Software for the ECAT HRRT PET Scanner Data
Methods and Models for Biological Signals and Images Research Group
Department of Signal Processing, Tampere University of Technology, Finland
Uygar Tuna, 08 September 2010


Notice:
The codes are provided without any warranty and for only research purposes. The developer cannot be held responsible for any bugs or mistakes in the provided codes. However the 
developer would appreciate the reported bugs or mistakes to (uygar{dot}tuna{at}tut{dot}fi). Do not distribute the codes without prior permission from the developer.
Contact: Uygar Tuna,
uygar{dot}tuna{at}tut{dot}fi.

The executable files provided on this page were compiled by using Matlab Compiler (Version 7.14) of Matlab 7.11.0(R2010b) in 32-bits WinXP operating system. In order to run executable files, Matlab compiler runtime program should be installed in your computer.

Gap_Fill_GUI.m, Gap_Fill_GUI.exe, Gap_Fill.m, Gap_Fill.exe (cc) Department of Signal Processing, Tampere University of Technology, Tampere, Finland, September 2010.


Matlab GUI File - (Gap_Fill_GUI.m / Gap_Fill_GUI.exe)

Please refer to Read_Me_GUI.pdf for instructions.

Matlab Source Codes: 
Gap_Fill_GUI.m
Gap_Fill_GUI.fig
filter.bmp  
parameters.txt


Executable File:
Gap_Fill_GUI.exe
parameters.txt


Matlab Command Line File - (Gap_Fill.m / Gap_Fill.exe)

Please refer to Read_Me_CL.pdf for instructions.

Matlab Source Codes:
Gap_Fill.m 
filter.bmp  
parameters.txt

Executable File:
Gap_Fill.exe
parameters.txt


Related Publications:
[1] U. Tuna, S. Peltonen, and U. Ruotsalainen, "Gap-Filling for the High Resolution PET Sinograms with a Dedicated DCT Domain Filter," IEEE Transactions on Medical Imaging, vol. 29, no.3, pp. 830-839, March 2010.
[2] U. Tuna, S. Peltonen, and U. Ruotsalainen, "Interpolation for the Gap-Filling of the HRRT PET Sinograms by Using the Slices in the Direction of the Radial Samples," IEEE Nuclear Science Symposium & Medical Imaging Conference (MIC2009), pp. 3273-3279, Orlando, Florida, USA, 25-31 October 2009.
[3] A. Loukiala, U.Tuna, S. Beer, S. Jahnke, and U. Ruotsalainen, "Gap-Filling Methods for the PlanTIS Data," Physics in Medicine and Biology, vol. 55, no. 20, pp.6125-6139, September 2010
[4] U. Tuna, S. Peltonen, and U. Ruotsalainen, "Data Estimation for the ECAT HRRT Sinograms Utilizing the DCT Domain" IEEE Nuclear Science Symposium & Medical Imaging Conference (MIC2008), pp. 5076-5080, Dresden, Germany, 19-25 October 2008.

Last Update: 7.12.2011

Creative Commons License
Gap-Filling Software for the ECAT HRRT PET Scanner Data by Uygar Tuna is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License.
Based on work shown in "Related Publications" above.